What was found
MAIN CABIN FLOOR SUPPORT ANGLE CRACKED AND BROKEN BS 540, RBL 1. ACFT GROUNDED. REMOVED THE FLOOR SUPPORT ANGLE AT BS 540, RBL-1 IAW SRM 51-40-02. RECEIVED THE NEW FLOOR SUPPORT ANGLE, PN 143A5240-36, LOCATED, DRILLED AND INSTALLED A NEW FLOOR SUPPORT ANGLE IAW SRM 51-40-02 AND DWG 143A5240, REV, REMOVED THE DOT.