What was found
RIGHT WHEEL WELL REAR SPAR, CENTER SECTION BETWEEN LBL-24.98-LBL-45.64 CRACKED, 2 EACH. ACFT GROUNDED. ACCOMPLISHED REPAIRS TO BS663 WING CENTER SECTION VERTICAL PRESSURE WEB BETWEEN LBL 10-LBL 50 IAW EA 700-57EA-15940, REV NEW, REO-G19236, REV A AND SRM 57-10-10-2R-3, REPAIR 3. ENGINEERING FOLLOW UP ACTION REQUIRED STAGE 1 APPROVAL FOR STATIC STRENGTH HAS BEEN GRANTED. STAGE 2 IS REQUIRED APPROVAL ON OR BEFORE OCTOBER 14,2017. WORK FRONT NOTIFICATION SENT. REFER TO DTI EC 700-57DTI-15941. DOT REMOVED.