What was found
AFT LOWER CARGO COMPARTMENT TRANSITIONAL PANEL CORRODED UPPER AND LOWER SURFACE SURFACE. NOT ALL AREAS MARKED, BS 727-BS 767, RBL 19-22. ACFT GROUNDED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. TRIMMED NEW TRANSITION PANEL AND LOCATED FASTENER HOLES & NUTPLATE HOLES IAW DWG 146A7502, REV A, APPLIED ALLODINE AND PRIMER AS REQUIRED IAW DWG 146A7502, REV B AND BAC 5719 AND BAC 5736, INSTALLED NUT PLATES, END CLIP AND PRODUCTION REINFORCEMENT DOUBLER ONTO NEW TRANSITION PANEL IAW SRM 51-40-02.