What was found
MAIN CABIN AFT FLOOR WEB, UPPER SURFACE, CORRODED, DOTTED,BS 986 - 988, RBL 30 - 45. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51-1A-1, FOUND TO BE BEYOND LIMITS IAW SRM 53-70-51-1A-1, FIG 103, DETAIL "C". FABRICATED DOUBLER AND FILLER IAW SRM 51-70-13-2R-3, ALODINED AND PRIMED IAW SRM 51-20-01, INSTALLED DOUBLER & FILLER IAW SRM 51-0-13-2R-3.