What was found
AFT FUSELAGE WET AREA, BS 987 +6, LBL 40 HAS CORROSION. ACFT GROUNDED. ORIGINAL MATERIAL THICKNESS .050", DAMAGED MATERIAL THICKNESS .007, REMAINING MATERIAL THICKNESS .043", FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51USING UT GAUGE TOOL T8225Z, REMOVED SUPPORT BRACKET IAW SRM 51-40-02, RECEIVED NEW SUPPORT BRACKET PN 147A5710Y1. LOCATED, REAMED AND COUNTERSANK FASTENER HOLES ON NEW SUPPORT BRACKET IAW SRM 51-40-08, INSTALLED NEW SUPPORT BRACKET IAW SRM 51-40-02, DOT REMOVED .