MAIN CABIN GIRT BAR ATTACH FLOOR FITTING CORRODED BS 344-BS 346, LBL 58-LBL 60. GROUNDED. R & R 141A5220-4, TIE DOWN FITTING IAW SRM 51-40-02. DOT REMOVED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN GIRT BAR ATTACH FLOOR FITTING CORRODED BS 344-BS 346, LBL 58-LBL 60. GROUNDED. R & R 141A5220-4, TIE DOWN FITTING IAW SRM 51-40-02. DOT REMOVED.