What was found
AFT CARGO COMPARTMENT FLOOR STRUCTURE AT BS 727 AND BS 727A AND LBL 12.5 HAS CORROSION. MARKED. ACFT GROUNDED. BLEND OUT CORROSION AREA, ORIGINAL MATERIAL THICKNESS .063 IAW DWG 1509-100146, MAT REMOVED .004, MAT REMAINING .059, FOUND TO BE WITHIN LIMITS IAW SRM 53-00-53-1A-2, ALODINE AND PRIMER IAW SRM 51-20-01, DOT V841, REMOVED.