As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO COMPARTMENT FLOOR STRUCTURE RT TRANSITION PANEL FROM BS 767 TO BS 787 HAS CORROSION, MARKED. ACFT GROUNDED. REMOVED CORROSION ON SHIELD, TRANSITION PANEL FROM BS 767 TO BS 787 IAW SRM 51-10-02. ORIGINAL THICKNESS IS .050. REMOVED DOT REMAINING THICKNESS IS .043. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53 AND SRM 53-60-53. R & R SHIELD IAW SRM 51-40-02 & DWG 146A8127, REV C DOT REMOVED.