What was found
VERTICAL STABILIZER PANELS 323BL, 323CL,AND 324AL LOWER SUPPORT ANGLE HAS CHAFING MARKS BETWEEN BS 1017 AND BS 1138, STR 2L AND 3L . ACFT GROUNDED. BLENDED AREA IAW SRM 51-10-02 & EA NG-55EA-03820, REV NEW FOUND TO BE OUT OF LIMITS AT BS 1124, ORIG .063 REMAINING .046, REMOVED .017, TOOL T8225Y CAL DUE 12-03-2015. REMOVED PANEL 324QL IAW AMM 55-33-31. REPAIRED IAW EA NG-55EA-03820, REV NEW INSTALLED PANEL 324QL IAW AMM 55-33-31 REMOVED DOT .