What was found
FUEL QTY NR 1 CB IS OUT. ACFT GROUNDED. RESET FUEL QTY NR 1 CIRCUIT BREAKER AND PERFORMED GVI INSPECTION, NO DEFECT NOTED IAW AMM 20-60-01. PERFORMED OPS TEST OF THE FUEL QUANTITY INDICATION, FOUND NORMAL, REF AMM 28-41-00-710-801.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUEL QTY NR 1 CB IS OUT. ACFT GROUNDED. RESET FUEL QTY NR 1 CIRCUIT BREAKER AND PERFORMED GVI INSPECTION, NO DEFECT NOTED IAW AMM 20-60-01. PERFORMED OPS TEST OF THE FUEL QUANTITY INDICATION, FOUND NORMAL, REF AMM 28-41-00-710-801.