What was found
DURING F/O PREFLIGHT AND FIRE DETECTION TEST WHEN FIRE/OVERHEAT SWITCH ENGAGED, FAULT, LIGHT ILLUMINATES AND FIRE HANDLE NR 2 DOES NOT ILLUMINATE. CYCLED THEN TEST PROCEDURE AND NOW OPS CHECK NORMAL. ACFT GROUNDED. ACCOMPLISHED FIM 26-10, TASK 801. NO FAULTS LOGGED, BITE TEST OK, GROUND VERIFICATION TEST OK.