Service difficulty report · Bleed Valve · Boeing 737990ER

Difficulty date
March 12, 2016
Submitted
March 15, 2016
Operation
Air carrier
Aircraft
N402AS
Make and model
Boeing 737990ER
Aircraft serial
41189
Aircraft time
13,371 hours, 4,334 cycles
Part
Bleed Valve
Part number
32145526
Part serial
9404
Condition
Failed
Location
Nr 2 Engine
Part time
36,320 hours, 11,028 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING CLIMB, THROUGH FL 260, RT BLEED FAILED. PERFORMED THE QRH AND RT BLEED DID NOT RESET AT CLIMB POWER OR WITH POWER REDUCED TO 90 PERCENT N1 IN THE CLIMB. AFTER 30 MIN AT CRUISE FLIGHT WE WERE ABLE TO RESET THE RT BLEED AT FL 350. RIGHT BLEED PSI WAS 43 WHEN THE BLEED FAILED AFTER RT BLEED RESET DUCT PRESS STABILIZED AT 15 PSI. ACFT GROUNDED. TROUBLESHOT RT PNEUMATIC BLEED SYS IAW AMM 36-11-00. FOUND PRSOV AND PCCV FAILED. R & R RT PRSOV IAW AMM 36-11-04. OPS AND LEAK CHECKS GOOD. R & R RT PCCV IAW AMM 36-12-02. OPS AND LEAK CHECKS GOOD. SUCCESSFUL GROUND VERIFICATION ACCOMPLISHED ON RT PNEUMATIC BLEED SYS.