What was found
FLIGHT CREW REPORTS AUTOLAND UNSUCCESSFUL. ACFT LANDED 30 FT RT OF CENTER LINE AND NO FLARE. FAILS LAND VERIFY BITE GROUP 49. HGS OPS TEST IAW AMM 34-36-00 NORMAL. ACFT GROUNDED. REVIEWED DFCS AND HGS IN-FLIGHT FAULTS. NO RELEVANT FAULTS FOUND EXCEPT ILS ANOMOLY FAULTS IN HGS LEGS 29 & 30. PERFORMED DFCS LIBRARY TEST GROUP NR 49, LAND VERIFY, REF AMM 22-11-00 AND HGS SYS TEST REF AMM 34-36-00. ALL TESTS PASS, NO FAULTS FOUND, REF AMM 22-00-01. AUTOLAND, OPS CHECKS GOOD. ACFT UPGRADED TO CAT IIIA AUTOLAND AND HGS CAPABLE.