Service difficulty report · Filter · Boeing 737990ER

Difficulty date
April 8, 2016
Submitted
April 11, 2016
Operation
Air carrier
Aircraft
N423AS
Make and model
Boeing 737990ER
Aircraft serial
35206
Aircraft time
11,827 hours, 3,828 cycles
Part
Filter
Part number
412N11687
Condition
Clogged
Location
Temp Sensor
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON RECALL CHECK LT PACK AMBER LIGHT ILLUMINATES. LIGHT GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE, NR 2 SHOWS NO FAULTS, NR 1 SHOWS THIS PACK TCV, VALVE 139. CLEARED FAULT. CLEANED ALL 3 CABIN TEMP SENSOR FILTERS AND REINSTALLED. RAN LT PACK FOR 60 MINUTES AND PACK LIGHT AND MASTER CAUTION REMAINED OFF. ACCOMPLISHED PACK TEMP CONTROL BITE, BOTH CONTROLLERS SHOW NO FAULTS, REF FIM 21-62, TASK 801, 21-62 TASK 830, AND AMM 21-61-06-100-801.