What was found
RIGHT SIDE WINDOW HEAT OVERHEAT LIGHT CAME ON DURING CLIMBOUT, TURNED IT OFF FOLLOWED QRH, LATER ON, CAME BACK ON. FLEW 3+ HOURS, NORMAL OPS. ON FINAL APPROACH, OVERHEAT LIGHT CAME BACK ON. WINDOW NEVER FELT HOT. ACFT GROUNDED. ACCOMPLISHED WHCU BITE, FOUND WINDOW SENSOR FAULT. CLEARED FAULT AND WINDOW HEAT, OPS CHECK GOOD, REF FIM 30-41-801.