Service difficulty report · Control Valve · Boeing 737990ER

Difficulty date
May 22, 2016
Submitted
May 24, 2016
Operation
Air carrier
Aircraft
N402AS
Make and model
Boeing 737990ER
Aircraft serial
41189
Aircraft time
14,180 hours, 4,603 cycles
Part
Control Valve
Part number
32149721
Part serial
3719
Condition
Failed
Location
Rt A/C Pack
Part time
14,180 hours, 4,603 cycles
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CABIN TEMP VERY HOT IN FWD CABIN 6-15, ROW, QRH FOLLOWED, CABIN TEMP LOWERED WITHIN SHORT TIME PERIOD. "TRIM SWITCH OFF". ACFT GROUNDED. BITE TESTED TEMP CONTROLLERS, REF FIM 21-61-00-810-801. VERIFIED FAULT, ACCESSED 4 CEILING PANELS FROM ROWS 6 TO 15, NO DEFECTS NOTED. CLOSED PANELS. ACCESSED FWD TEMP FAN, REPLACED FAN SENSOR WITH NEW ONE, CLEANED FILTER & TEMP BULB. CLOSED PANEL. ACCOMPLISHED CABIN TEMP BULB TEST, TEST FAIL BOTH FWD AND AFT ZONES. REPLACED CABIN TEMP INDICATOR, NO HELP, REINSTALLED ORIGINAL PART. CHECKED GROUNDS AT INDICATOR CONNECTION D90, FOUND BAD RESISTANCE. REPLACED CONNECTOR & SOCKETS FOR D90 & RECONNECTED TO INDICATOR. DURING T/S FOUND V146, PRSOV, STUCK IN CLOSED POSITION IN BOTH ON & OFF. REPLACED V146 WITH NEW ONE. ACCOMPLISHED INSTALLATION TEST FOR V146 & BOTH CABIN TEMP BULBS & FAN SENSOR ALL PASS. REF AMM 21-51-11-400-801, 21-61-31-400-801, 21-61-32-400-801, WDM 21-61-51, SWPM 20-60-11 & AMP 5-07-01.