What was found
ENGINE NR 2 OVERHEAT LIGHT DOES NOT ILLUMINATE DURING FIRE TEST. ACFT GROUNDED. FIRE DETECTION UNIT BITE TEST. R & R MULTIPLE DETECTORS, M279 MODULE, AND WIRING HARNESS FOR WORK ACCOMPLISHED. OPS CHECK GOOD, NO DEFECTS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ENGINE NR 2 OVERHEAT LIGHT DOES NOT ILLUMINATE DURING FIRE TEST. ACFT GROUNDED. FIRE DETECTION UNIT BITE TEST. R & R MULTIPLE DETECTORS, M279 MODULE, AND WIRING HARNESS FOR WORK ACCOMPLISHED. OPS CHECK GOOD, NO DEFECTS NOTED.