What was found
AFTER POWER INTERRUPTION, F/O'S PFD DISPLAYS FD AMBER WARNING, ALSO, F/O'S FD SWITCH TURNED TO ON, THERE'S NO FD OR MA ON F/O'S SIDE. ACFT GROUNDED. CYCLED POWER, OPS NORMAL, DUE TO WEAK GPU, ACCOMPLISHED DFCS BITE NO FAULTS NOTED, REF FIM 22-11, TASK 801, ETOPS SIGNIFICANT SYS GROUND VERIFICATION SUCCESSFUL.