What was found
BOTH GREEN LIGHTS IN "HDG SEL" BUTTTON ON AFCS MCP INOP. ALL BUTTON FUNCTIONS ARE NORMAL. ACFT GROUNDED. REMOVED AND REPLACED MODE CONTROL PANEL IAW AMM 22-11-34-740-80, OPS NORMAL IAW AMM 22-11-34-740-801. ACCOMPLISHED DFCS MCP LRU INTERFACE TEST, GROUP BITE 32 AND LAND VERIFY TEST, GROUP BITE 49, BOTH TEST PASSED IAW AMM 22-11-00/201. ACCOMPLISHED HGS FCC/AT SENSOR DATA TEST, OPS NORMAL, IAW MMS 34-36-00.