What was found
AFTER LANDING, SINGLE FMC OPERATION, SHOWN ON FMC SCRATCHPAD. ACFT GROUNDED. REF FIM 34-61, TASK 801, LT FMC SHOWED AN ETHERNET-2 WRAP FAULT. REF OEM 34-61, TASK 837, HARDWARE FAILURE. REF AMM 34-61-02, REMOVED, REPLACED NR 1 FMC COMPUTER. PERFORMED SOFTWARE CROSS LOAD FROM FMC-2 REF 34-61-00. OPS CHECK GOOD, REF AMM 34-61-02/34-61-00. GROUND VERIFICATION TEST GOOD REF SAME AMM'S. FMC TRANSFER SWITCH MOVED TO NORMAL. THIS CLEARS MEL 34-36J.