What was found
PARTS RACK, AFT PIT FLOOR PANEL 140BF AFT END SPLICE TEE CORRODED. ACFT GROUNDED. REPLACED WITH NEW SPLICE TEE ASSY IAW DWG 146A9401. CORROSION FOUND TO BE OUT OF LIMITS, EXFOLIATED, IAW SRM 53-00-53.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PARTS RACK, AFT PIT FLOOR PANEL 140BF AFT END SPLICE TEE CORRODED. ACFT GROUNDED. REPLACED WITH NEW SPLICE TEE ASSY IAW DWG 146A9401. CORROSION FOUND TO BE OUT OF LIMITS, EXFOLIATED, IAW SRM 53-00-53.