What was found
FWD CARGO BAY FLOORBOARD 120AF HAS MULTIPLE AREAS OF DAMAGE THAT ARE OUT OF LIMITS IAW SRM 53-00-53-1A-1. ACFT GROUNDED. FABRICATED A NEW FLOORBOARD IAW DWG 453A1610 REV F, ALODINED, & PRIMED IAW SRM 51-20-01 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO BAY FLOORBOARD 120AF HAS MULTIPLE AREAS OF DAMAGE THAT ARE OUT OF LIMITS IAW SRM 53-00-53-1A-1. ACFT GROUNDED. FABRICATED A NEW FLOORBOARD IAW DWG 453A1610 REV F, ALODINED, & PRIMED IAW SRM 51-20-01 .