What was found
MAINT ENTRY: DURING FIRE TEST OF FIRE DISCHARGE HANDLES, NR 1 FIRE DISCHARGE HANDLE LIGHTS INOPERATIVE. ACFT GROUNDED. TROUBLESHOT IAW FIM 26-10 TASK 801, FAULT 31 ENG WIRING OPEN FOR DETECTOR FAULT A LOOP. GVI DETECTOR LOOP A, FOUND LOOSE TERMINAL ON LT CORE DETECTOR M1759 LOWER TERMINAL. CLEANED TERMINAL AND SECURED IAW AMM 26-11-01-400-801. BITE TEST AND SYS GROUND VERIFICATION TEST OK IAW AMM 26-11-00-710-801.