What was found
NR 2 START VALVE REMAINED OPEN AFTER ENGINE START. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 START VALVE. OPS & LEAK CHECKED GOOD IAW MM 80-11-03 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 START VALVE REMAINED OPEN AFTER ENGINE START. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 START VALVE. OPS & LEAK CHECKED GOOD IAW MM 80-11-03 .