What was found
NO LIGHTS DISPLAYED ON FLT CONTROL PANEL. ACFT GROUNDED. CYCLED POWER, LIGHTS ON MCP RESTORED, PERFORMED DFCS CURRENT STATUS IAW FIM 22-11 TASK 801, NO CURRENT FAULTS, ACCOMPLISHED MCP BITE GRP 32 IAW AMM 22-11-34. ALL TESTS PASSED NO HISTORY 30 DAYS. ALL GROUND FUNCTIONAL TESTS PASSED. ACCOMPLISHED BITE GRP 49 LAND VERIFY AMM 22-11-00, ALL GROUND FUNCTIONAL TESTS PASSED.