Service difficulty report · Sensor · Boeing 737990ER

Difficulty date
October 24, 2017
Submitted
October 25, 2017
Operation
Air carrier
Aircraft
N403AS
Make and model
Boeing 737990ER
Aircraft serial
41730
Aircraft time
19,949 hours, 6,549 cycles
Part
Sensor
Condition
Failed
Location
Temp
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FWD CABIN CONTROLLER SPIKED UP TO 55C UNCOMMANDED. IT DID RESPOND TO COOLER TEMP INPUTS. ACFT GROUNDED. FOUND FWD CABIN ZONE TEMP SENSOR FAN NOT RUNNING. THE FAN BEGAN TO RUN WHILE LOWERING THE PSU. REPLACED FWD ZONE CABIN TEMP SENSOR ASSEMBLY DUCT INSTALLATION ALONG WITH ASSOCIATED FAN AND SENSORS IAW AMM 21-61-14. OPS NORMAL IAW AMM 21-61-00. GROUND VERIFICATION ACCOMPLISHED.