What was found
AFT CABIN FLOOR INTERCOSTAL STA 947.5-967 LBL 24 CORRODED. GROUNDED - YES. BLENDED CORROSION, ORIGINAL THICKNESS .150, MATERIAL REMAINING .130, REMOVED .020, OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1. REMOVED AND REPLACED INTERCOSTAL P/N 147A5660-3 IAW BAC DWG 147A5650 REC A AND B737-800 SRM 51-40-02. DOT REMOVED.