What was found
NR 1 IDG REQUIRES FREQUENT SERVICING. ACFT GROUNDED. ACCOMPLISHED A NR 1 IDG STATIC LEAK CHECK IAW AMM 24-11-00. FOUND EVIDENCE OF A LEAK AT THE IDG AIR/OIL COOLER. REPLACED THE IDG AIR/OIL COOLER IAW AMM 24-11-21. LEAK CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 IDG REQUIRES FREQUENT SERVICING. ACFT GROUNDED. ACCOMPLISHED A NR 1 IDG STATIC LEAK CHECK IAW AMM 24-11-00. FOUND EVIDENCE OF A LEAK AT THE IDG AIR/OIL COOLER. REPLACED THE IDG AIR/OIL COOLER IAW AMM 24-11-21. LEAK CHECKED GOOD.