What was found
ZONE TEMP LIGHT TURNS ON AFTER DOING A MASTER CAUTION RECALL THE ZONE TEMP LIGHT WILL RESET. GROUNDED - YES. CONFIRMED FAULT. CABIN ZONE TEMP LIGHTS ILLUMINATE DURING MASTER CAUTION RECALL. PERFORMED NR 1 AND NR 2 CABIN TEMP CONTROLLER BITE REF FIM 21-61. NR 1 OPS NORMAL. NR 2 HAS TRIM VALVE FLT DECK FAULT. FAULT CLEARED AFTER RESET. RUN PACKS. NO FAULTS. NO HISTORY IN THE PAST 30 DAYS. THIS CLEARS MEL 21-21F.