Service difficulty report · Valve · Boeing 737990ER

Difficulty date
April 8, 2018
Submitted
April 10, 2018
Operation
Air carrier
Aircraft
N468AS
Make and model
Boeing 737990ER
Aircraft serial
41735
Aircraft time
15,026 hours, 5,026 cycles
Part
Valve
Condition
Faulted
Location
Temp System
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ZONE TEMP LIGHT TURNS ON AFTER DOING A MASTER CAUTION RECALL THE ZONE TEMP LIGHT WILL RESET. GROUNDED - YES. CONFIRMED FAULT. CABIN ZONE TEMP LIGHTS ILLUMINATE DURING MASTER CAUTION RECALL. PERFORMED NR 1 AND NR 2 CABIN TEMP CONTROLLER BITE REF FIM 21-61. NR 1 OPS NORMAL. NR 2 HAS TRIM VALVE FLT DECK FAULT. FAULT CLEARED AFTER RESET. RUN PACKS. NO FAULTS. NO HISTORY IN THE PAST 30 DAYS. THIS CLEARS MEL 21-21F.