What was found
NR 1 A/C PACK REGULATOR FAULTED. ACFT GROUNDED. ACCOMPLISHED COMPUTER RESET IAW TSM 24-00-00-810-818, AIRCRAFT OK FOR SERVICE. REMOVED AND REPLACED THE P1 COMP TEMP (12HH) SENSOR IAW AMM 21-61-11, PB401, CONF 00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 A/C PACK REGULATOR FAULTED. ACFT GROUNDED. ACCOMPLISHED COMPUTER RESET IAW TSM 24-00-00-810-818, AIRCRAFT OK FOR SERVICE. REMOVED AND REPLACED THE P1 COMP TEMP (12HH) SENSOR IAW AMM 21-61-11, PB401, CONF 00.