What was found
FWD CARGO COMPARTMENT FLOOR RT ZEE CHANNEL UPPER SURFACE CORROSION STA 500C+14 TO 500L NUMEROUS AREAS MARKED. GROUNDED - YES. REMOVED CORROSION FROM STA 500I TO 500L. ORIG THICKNESS .040, REMOVED .010, REMAINING .030. FOUND TO BE OUT OF LIMITS IAW SRM 51-40-02. FABRICATED REPAIR PARTS IAW SRM 53-00-53-2R-5. ALODINED PARTS IAW AMM 51-21-41. PRIMED PARTS IAW AMM 51-21-72. INSTALLED REPAIR PARTS AD SUBSTRUCTURE IAW SRM 53-00-53-2R-5 AND 51-40-02.