What was found
DURING PREFLIGHT, THE NR 2 ENGINE VALVE CLOSED LIGHT ILLUMINATED BRIGHT BLUE. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 HMU, OPS AND LEAK CHECKED GOOD, ENGINE VALVE CLOSED LIGHT OPERATES NORMALLY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING PREFLIGHT, THE NR 2 ENGINE VALVE CLOSED LIGHT ILLUMINATED BRIGHT BLUE. ACFT GROUNDED. REMOVED AND REPLACED THE NR 2 HMU, OPS AND LEAK CHECKED GOOD, ENGINE VALVE CLOSED LIGHT OPERATES NORMALLY.