Service difficulty report · Sensor · Boeing 737890

Difficulty date
June 11, 2018
Submitted
June 14, 2018
Operation
Air carrier
Aircraft
N570AS
Make and model
Boeing 737890
Aircraft serial
35185
Aircraft time
43,164 hours, 12,812 cycles
Part
Sensor
Condition
False Activation
Location
Window
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NR 2 WINDOW OVERHEAT LIGHT ILLUMINATED DURING APPROACH. ACFT GROUNDED. TROUBLESHOT IAW FIM 30-41, TASK 811. CURRENTLY FAULT LIGHT WAS NOT ON. PERFORMED A WINDOW HEAT CONTROL UNIT BITE IAW FIM 30-41 TASK 801, TEST PASSED. PREVIOUS LEG FAULTED WINDOW SENSOR. PERFORMED A CHECK OF THE WINDOW SENSORS AND FOUND VALUES TO BE WITHIN LIMITS. DISCOVERED WINDOW WAS ALREADY USING SPARE SENSOR. REMOVED AND REPLACED THE FIRST OFFICER`S WINDOW ASSY IAW AMM 56-12-11. LEAK TESTED AND OPS CHECKED GOOD.