What was found
STAB TRIM MOTOR FAILED TEST PER AMM 22-11-81-710-801, AMM 27-41-00-700-801, ACCOMPLISHED STAB ELEC TRIM SYSTEM TEST REF AMM 27-41-00-700-803, TEST NORMAL, COULD NOT DUPLICATE FAILED TEST. UNABLE TO PERFORM LAND VERIFY DUE TO FCC-A FAILURE. SUSPECT STAB POS SENSOR 01, FCC-A. AUTOPILOT A INOP, A/T INOP. GROUNDED - YES. ACCOMPLISHED STAB POS SENS ADJ & TEST REF AMM 22-11-31/501. ADJUSTED CH A SENSOR TO WITHIN LIMITS. ACCOMPLISHED DFCS LRU REPLACEMENT TEST FOR STAB SENS, GRP 44, REF AMM 22-11-31/501. ALL TESTS PASSED. ACCOMPLISHED A/T SYS OPERATIONAL TEST REF AMM 22-31-00-710-801. ALL TESTS PASSED. ACCOMPLISHED LAND VERIFY TEST, GRP 49, REF AMM 22-11-00-700-801. ALL TESTS PASSED.