What was found
LOWER ATTACH ANGLE, ATTACHED TO THE VERTICAL PRESSURE DECK WEB AT BS 663, LBL 25-LBL 45, CRACKED FROM WEB SLOT TO THE FIRST/LOWER INBOARD DOME NUT ATTACH FASTENER HOLE. GROUNDED - YES. REMOVED DAMAGE ON THE LOWER ATTACH ANGLE IAW SRM 51-10-02. ACCOMPLISHED HFEC INSPECTION OF THE TRIM EDGES IAW NDT MANUAL 51-00-00 PART 6 PROCEDURE 23, NO CRACK INDICATIONS. REPAIRED LOWER ATTACH ANGLE IAW EA 800-57EA 20694 REV 00. ACCOMPLISHED THE VERTICAL PRESSURE WEB MODIFICATION PER SB737-57-1330 AT BS663, LBL 25-LBL 45 IAW EA 800-57EA-20694 REV OO. REPAIR AS ACCOMPLISHED IS CONSIDERED A CATEGORY "A" REPAIR.