What was found
MAIN CABIN FLOORBEAM AT BODY STATION 947.5 CORRODED AT LBL 16. GROUNDED - YES. REMOVED CORROSION IAW SRM 53-70-15-1A-1 FIG 104 DET D. ORIGINAL THICKNESS .180" REMOVED, .059" REMOVING .121" FOUND TO BE OUT OF LIMITS. FABRICATED, MODIFIED, ALODINED, PRIMED, AND INSTALLED REPAIR T-CHORD, ANGLES, STRAPS AND FILLERS IAW SRM 53-70-51-2R-5 REPAIR 5.