Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
October 1, 2018
Submitted
October 4, 2018
Operation
Air carrier
Aircraft
N517AS
Make and model
Boeing 737890
Aircraft serial
35197
Aircraft time
37,745 hours, 11,181 cycles
Part
Modulating Valve
Part number
3989083
Part serial
11258
Condition
Failed
Location
Ac Bay
Part time
36,551 hours, 11,321 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT PACK LITE ILLUMINATED ON RECALL. EXTINGUISHED WHEN MASTER CAUTION PUSHED. GROUNDED - YES. VERIFIED BITE CHECK NR 1 TEMP CONTROLLER SHOWS "THIS PACK TCV" FAULT. REMOVED AND REPLACED LEFT PACK TEMPERATURE CONTROL VALVE REF AMM 21-51-10. TEST GOOD. NO LEAKS NOTED, LEFT PACK LIGHT DID NOT RETURN.