What was found
ENG # 2 FAULT MSG # 75-20832.THE T3 SIGNAL IS OUT OF RANGE. FLIGHT LEG: 1. LONG TIME FAULT. DEFERRED PER TASK CARD. GROUNDED - YES. PERFORMED B737-800 FIM 75-33 TASK 802. FOUND T3 CHANNEL A CONNECTOR WITH CORROSION. CLEANED THOROUGHLY. RECONNECTED AND SAFETIED. PERFORMED EEC BITE TEST-RECENT FAULTS REF B737-800 AMM 73-21-00-740-803-F00. NO FAULTS WERE LOGGED SINCE T3 SENSOR CONNECTOR CLEANING. ALSO PERFORMED EEC TEST FOR #2 ENGINE REF AMM 73-21-00-700-804-F00 - ALL TESTS PASSED. NO FAULTS NOTED.