Service difficulty report · Actuator · Boeing 737890

Difficulty date
March 1, 2019
Submitted
April 11, 2019
Operation
Air carrier
Aircraft
N590AS
Make and model
Boeing 737890
Aircraft serial
35687
Aircraft time
42,411 hours, 12,777 cycles
Engine
Cfmint CFM567B27B3
Part
Actuator
Part number
1324M12P10
Part serial
APMRG019
Condition
Defective
Location
Nr 1 Engine
Part time
42,624 hours, 12,676 cycles
Stage of operation
IN
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE PERFORMING T/C #7827300 FOUND LONG TIME FAULT MESSAGE #75-20391 "THE VSV POSITION SIGNAL IS OUT OF RANGE." DEFERRED PER T/C #78273000 ON NR 1 ENG. GROUNDED - YES. REMOVED AND REPLACED THE NR 1 ENG LT VSV ACTUATOR, LEAK CHECK GOOD. ACTUATOR TEST PASS AND NO FAULTS FOUND AFTER RUN. REF AMM 75-31-01-000-801-F00 AND 75-31-01-400-801-F00. THIS CLEARS PLT DEFERRAL.