What was found
DURING THE PRE-FLIGHT, NOTICED THE "ELEC" AMBER LIGHT IS ILLUMINATED. THE ELECTRICAL HYDRAULIC PUMPS ALSO DID NOT TURN ON WHEN THE SWITCHES WERE PLACED TO THE "ON" POSITION. GROUNDED - YES. PERFORMED FIM 24-34 TASK 801, BITE SHOWS "SPCU INOP". PERFORMED FIM 24-34 TASK 802, FAULT CLEARED. ALSO FOUND CB'S FOR ELECT HYD PUMP SYS A AND ELECT HYD PUMP SYS B OUT. INSPECTED AREA, NO DISCREPANCIES FOUND, RESET CB'S, REF AMM 20-60-01. OPS CHECK OF EMDP'S NML, REF AMM 29-11-00. BITE CHECK OF ELECTRICAL METERS MODULE NML, REF FIM 24-34 TASK 801.