What was found
AFTER STARTING THE APU THE BLUE MAINT LIGHT CAME ON. AFTER WE SHUT DOWN THE APU THE FAULT LIGHT ILLUMINATED. GROUNDED - YES. REMOVED AND REPLACED APU STARTER GENERATOR. REF B737-800 AMM TASK 49-41-21-000-881 AND AMM 49-41-21-400-801. NO HELP. REMOVED AND REPLACED START CONVERTER UNIT IAW AMM 49-41-61. INSTALLATION TEST GOOD PER AMM 49-41-61 STARTER GEN OPS CHECKS GOOD PER AMM 49-41-21. ETOPS GROUND VERIFICATION GOOD.