What was found
FOUND #2 ENG LONG TIME FAULT 75-20832 THE T3 SIGNAL IS OUT OF RANGE. GROUNDED - YES. ACCOMPLISHED #2 EEC BITE B737-800 FIM 73-00 TASK 801. TEST RESULT SHOWS FAULT 75-20832. INSPECTED INPUT MONITORING AND FOUND T3 CHANNEL B SHOWING DASHES. ACCOMPLISHED CONNECTOR CLEANING PER FIM 75-33 TASK 802. INDICATION RETURNED TO NML. T3 CHA READS 111.07, CHA B READS 111.60. SYS IS WORKING NML. ACCOMPLISHED EEC BITE AGAIN AND NO FAULTS SHOWED.