Service difficulty report · Valve · Boeing 737890

Difficulty date
August 20, 2019
Submitted
October 8, 2019
Operation
Air carrier
Aircraft
N590AS
Make and model
Boeing 737890
Aircraft serial
35687
Aircraft time
44,235 hours, 13,333 cycles
Engine
Cfmint CFM567B27B3
Part
Valve
Part number
32913903
Part serial
GRTU2785C
Condition
Out Of Tolerance
Location
Nr 2 Bleed
Part time
53,744 hours, 21,442 cycles
Stage of operation
IN
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE ACCOMPLISHING TASK CARD 782730, INTERROGATE THE FMC CDU. MAINT MESSAGE: 75-10592. "THE TBV POSITION SIGNAL IS OUT OF RANGE" LONG TIME FAULT. #2 ENG. GROUNDED - YES. ENG #2 FAULT 75-10592 IS LONG TIME FAULT. TO BE REPAIRED W/IN 450 FLT HRS. DEFERRED PER T/C 78273000. REMOVED AND REPLACED #2 ENG TRANSIENT BLEED VALVE IN REF TO B737-800 AMM 75-23-01-400-801-F00 OPS AND LEAK CK GOOD.