What was found
APU AUTO SHUTDOWN ON TAXI IN GROUNDED - YES. R&R APU IGNITION PLUG REF AMM 49-41-41. OPS TEST OF APU AT 33% GENERATOR LOAD GOOD. A/C RELEASED FROM MEL 49-10-01-01, MAINTENANCE PROCEDURE REVERSED, MDDR 71133 REMOVED, SEAMC NOTIFIED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU AUTO SHUTDOWN ON TAXI IN GROUNDED - YES. R&R APU IGNITION PLUG REF AMM 49-41-41. OPS TEST OF APU AT 33% GENERATOR LOAD GOOD. A/C RELEASED FROM MEL 49-10-01-01, MAINTENANCE PROCEDURE REVERSED, MDDR 71133 REMOVED, SEAMC NOTIFIED.