As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 1 ENG A LOOP INOP. GROUNDED - YES. ACCOMPLISHED FIRE DETECTION CONTROL MODULE BITE TEST PER FIM 26-10 TASK 801. PERFORMED VISUAL INSPECTION OF FIRE LOOPS AND HARNESSES FOUND RT CORE A LOOP WIRE BROKEN AT TERMINAL LUG. REPLACED TERMINAL PER AMM 26-11-002-960-802. TERMINAL REPLACEMENT IS APPLICABLE PER WIRE HARNESS P/N 325-027-506-0 HARNESS IS CORRECT EFFECTIVELY FOR AIRCRAFT.