What was found
APU FAULT LIGHT ILLUMINATED DURING START. GROUNDED - YES. PERFORMED APU BITE ON CDU, FOUND FAULT 49-41011 "NO FLAME SHUTDOWN". STARTED & OPERATED APU TWICE REF B737-900 AMM 49-11-00/201 WITH NO DEFECTS NOTED. APU OPERATES NORMALLY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAULT LIGHT ILLUMINATED DURING START. GROUNDED - YES. PERFORMED APU BITE ON CDU, FOUND FAULT 49-41011 "NO FLAME SHUTDOWN". STARTED & OPERATED APU TWICE REF B737-900 AMM 49-11-00/201 WITH NO DEFECTS NOTED. APU OPERATES NORMALLY.