What was found
REF L/P 12301081. DURING ACCOMPLISHING LAND VERIFY (AUTOLAND) FAULT MSG 22-11125. GROUNDED - YES. VERIFIED FAULTS 22-11125 AND 22-11126 DURING BITE LIBRARY TEST 60.32. REPLACED THE ELEVATOR SENSOR REF B737-900 AMM 22-11-30/401. COMPLETED ADJUSTMENT. NO HELP TO ORIGINAL DEFECT. REPLACED F/O'S COLUMN CUTOUT SWITCH M1201 REF AMM 27-41-51/401. ADJUSTMENT AND OPS CHECK GOOD. ACCOMPLISHED INSTALLATION TEST OF THE ELEVATOR POSITION SENSOR IAW AMM 22-11-30-820-801. GROUND VERIFICATION TESTS ARE GOOD.