What was found
DUCT PRESSURE SPLIT 22 PSI, L PRESS 42, R PRESS 20. L PRESS WOULD SPIKE UP TO 5 MORE PSI PERIODICALLY. DURING LOWER POWER SETTINGS IE DECENT DIFF PRESS WOULD EQUALIZE. GROUNDED - YES. ACCOMPLISHED ENG NR 2 BLEED AIR SYSTEM HEALTH CHECK REF T/C NG-36WC-00001. FOUND BAR LEAKING, REMOVED & REPLACED NR 2 ENG BAR REF AMM 36-11-03.