What was found
AFT CARGO PIT RT SIDE UNDER PANEL 142FW, STA787, STR25R, CORROSION AT AND AROUND BRACKET. STREAMER ATTACHED. GROUNDED - YES. BLENDED CORROSION ON SHIELD AT STR 25R STA 787 FOUND TO BE OUT OF LIMITS, PER SRM 53-60-15-1A. REMOVED SHIELD AND GUSSET, REPLACED SHIELD WITH NEW P/N 146A8127U12 PO# 979659.1. INSTALLED EXISTING GUSSET, REF B737-800 SRM 51-40-05; 51-40-02 AND DWG 146A0081 REV.