What was found
STA 328 FLOORBEAM CORRODED BETWEEN LBL 34 AND RBL 56. GROUNDED-YES. REPAIRED FLOORBEAM, IAW 737-700 SRM 53-10-51-2R-7W-1 O-.125 R-.103 L-1 D-.022.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 328 FLOORBEAM CORRODED BETWEEN LBL 34 AND RBL 56. GROUNDED-YES. REPAIRED FLOORBEAM, IAW 737-700 SRM 53-10-51-2R-7W-1 O-.125 R-.103 L-1 D-.022.